- Includes Plug and Pins
- Push wire through connector; crimp on terminal; pull wire/terminal back into connector
- Using Link G4/G4+/G4X ECU’s select the MAP sensor type in PC Link as ‘Variohm 5 Bar’
Calibration – 0kpa = 0.5v, 500kpa = 4.5v
PIN A = 0v
PIN B = 5v
PIN C = Signal